13 · Evidence Observatory

Every number, graded

The Atlas treats evidence quality as a first-class dimension. This page is the audit trail: which fields are reported by operators, which are documented estimates, which are class-band inferences, and where the dataset is simply silent.

Documented parameters
0
fields with a provenance record
Mean field confidence
0.00
of 5 across all parameters
Quality-control checks
0
reconciliations against published data
Checks flagged
0
divergences documented rather than adjusted

Confidence distribution across parameters

Count of documented fields in each confidence band. The bulk of this dataset is modelled, not reported.

Reading the grades

What each confidence level means

4–5 · reported

Published by the operator or a regulator, in a named document.

3 · documented estimate

Derived from a credible published figure with a stated method.

2 · modelled

Computed from documented coefficients applied to this facility.

1 · class-band inference

Assigned from a facility-class or land-use band, not this facility.

0 · no record

No value located. Shown as an em dash, never as a zero.

Structural silence

The field does not exist in the dataset: Scope 1, Scope 3, measured noise, metered energy.

Audit trail

Provenance

Field / parameterUnitEvidence typeConfidenceDerivationSourceLimitation
Data_Centre_IDidDerived5.0/5ISO3 country code + sequential number. Stable primary key across every sheet.This workbookNot an external identifier; do not join to third-party datasets on it.
Data_Centre_NametextReported4.0/5Facility name as published by the operator or a market directory.Operator sites; datacentermap.com market directoriesNaming conventions differ between operators; some campus and building rows share a stem.
OperatortextReported4.0/5Owning or operating company at the time of compilation.Operator disclosures and market directoriesOwnership changes frequently (M&A, JV, sale-leaseback). Snapshot as at 2026-08-25.
Record_TypecategoryDerived5.0/5Facility = a single data centre building. Campus = a multi-building parent, EXCLUDED from all sums.This workbookCampus rows exist only to preserve the parent-child structure.
Country / Region / State_Province / CitytextReported4.0/5Administrative geography of the facility's area.Facility addressesCity is the administrative city of the AREA, which for metro-fringe sites may differ from the marketed city.
Latitude / Longitudedecimal degreesProxy2.0/5Centroid of the facility's industrial estate, business park or suburb.Area reference table, sheet 52AREA CENTROID, NOT a rooftop coordinate. +/-1-3 km typically, +/-5-15 km for city-centroid records.
Coordinate_PrecisioncategoryDerived5.0/5Declares which of the two precision bands the coordinate belongs to.This workbook
StatuscategoryReported/Inferred3.0/5Operational, Under construction, Announced, Planned or Unknown.Market directories and operator announcementsDirectories do not always disaggregate status; some Operational flags are inferred from listing context.
Year_OnlineyearReported or Modelled1.0/5Reported commissioning year where found; otherwise back-cast (Methodology section 6).Operator announcements; sourced national capacity curvesConfidence 1 for every modelled year. Do not use for individual-site vintage claims.
Capacity_MW_IT_2026MWReported or Allocated2.0/5Energised IT-load capacity. Reported where published; otherwise market-anchor allocation (Methodology section 3).Market anchors in sheet 51; operator disclosuresAn allocation for 1094 of 1098 facilities. Individual values are indicative; market and cluster sums are the reliable level.
Capacity_MW_UltimateMWAllocated2.0/5Capacity at full build-out of the identified pipeline, before the status energisation factor.As aboveAssumes announced and planned schemes complete at the same class weight as built stock.
PUEratioReported or Proxy2.0/5Operator fleet/design PUE where published; otherwise the country-climate benchmark.Operator sustainability reports; Uptime Institute regional averagesA fleet average applied to one site. Real site PUE varies with load factor, age and season.
Load_FactorfractionModelled2.0/5Average IT-load utilisation by facility class (Hyperscale 0.80, Wholesale 0.65, Mid colo 0.60, Small 0.50).Operator disclosures; JLL/CBRE colocation occupancy; LBNL 0.50 fleet assumptionSingle annual constant; ignores ramp-up on newly commissioned halls.
Energy_Consumption_MWh_yrMWh/yrModelled2.0/5Capacity x 8,760 x Load_Factor x PUE.Derived in this workbookNo site is metered here. Error compounds capacity error, load-factor error and PUE error.
Energy_Intensity_MWh_per_MW_yrMWh/MW/yrDerived2.0/58,760 x Load_Factor x PUE.DerivedVaries only by class and country in this build; it is not a site-specific efficiency measure.
Grid_Electricity_Dependence_pct%Proxy1.0/5Set to 100 for every facility.Absence of published behind-the-meter generation dataNo public evidence of material on-site generation was located at any facility. Treat as an upper bound.
Renewable_Grid_pct%Reported3.0/5National grid-average renewable share of GENERATION.Ember / national statistical agenciesA physical grid mix, NOT contracted or matched procurement. Do not confuse with the next field.
Renewable_Matched_pct%Reported4.0/5Operator-published renewable matching / carbon-free-energy percentage, where one exists.Operator sustainability reportsAnnual matching, not hourly delivery, except where the operator states otherwise (Google reports hourly CFE).
Water_Consumption_m3_yrm3/yrModelled2.0/5Energy_MWh x WUE.DerivedOn-site cooling water only. Excludes upstream water embodied in electricity generation, which is often larger.
WUEm3/MWh (= L/kWh)Reported or Proxy2.0/5Operator fleet WUE where published; otherwise country-climate benchmark.Operator reports; source workbook benchmarksUK, EU and Irish values are climate proxies with no primary national data-centre figure. Singapore's is a regulatory CEILING.
Water_Stress_Score / Label0-5 / categoryProxy2.0/5WRI Aqueduct-informed baseline water-stress band for the facility's basin.WRI Aqueduct Water Risk Atlas, area-level interpretationNOT a real Aqueduct basin lookup against the facility coordinate. Assigned per reference AREA.
Water_Stress_Weighted_Demand_m3m3/yrDerived2.0/5Water_m3 x (water-stress score / 5). A scarcity-adjusted demand.DerivedLinear scarcity weighting is a convention, not a hydrological model.
Cooling_Water_DependencecategoryModelled2.0/5Banded from WUE: >1.5 evaporative-dominant, 0.5-1.5 hybrid, <0.5 air-cooled/closed-loop.Derived from WUEInferred from a water ratio, not from the installed plant.
Carbon_Emissions_Location_tCO2e_yrtCO2e/yrModelled2.0/5Energy_MWh x national grid emission factor.National grid emission factors, sheet 51LOCATION-BASED Scope 2. National averages hide large sub-national variation (~6x across US eGRID subregions).
Carbon_Emissions_Market_tCO2e_yrtCO2e/yrModelled3.0/5Energy_MWh x grid factor x (1 - operator matched-renewable %).Operator disclosuresOnly populated where the operator publishes a matching percentage. Annual matching is not hourly decarbonisation.
Emission_Intensity_tCO2e_per_MWhtCO2e/MWhReported3.0/5The national grid emission factor applied to that facility.National regulators / EPA / CEA / UBA / EMAUniform within a country by construction.
Waste_Heat_MW_thermal / _TJ_yrMWth / TJ/yrDerived3.0/5Energy_MWh / 8,760, and the same energy expressed as TJ per year.Energy-balance proxy, same method as the supplied workbookAn average annual heat-rejection RATE, not a measured local temperature effect.
Cooling_TechnologycategoryModelled1.0/5Inferred from WUE band.Derived from WUEA guess at plant type from a water ratio. Replace with planning-application data where available.
Mean_Annual_Temperature_Cdeg CProxy3.0/5Long-run mean annual air temperature for the facility's area.Climate normals, area-levelAnnual mean; ignores the summer peak that actually drives cooling and heat-island effects.
Heat_Island_ProxyMWth x k-persons/km2Derived1.0/5Waste_Heat_MW x resident density / 1,000.DerivedA composite index with no physical units meaning. Comparative only.
Noise_dBdB(A) @ ~50 mModelled1.0/550 + 10 x log10(Capacity_MW), clipped to [45,85].Engineering proxy anchored to the Prince William County 60 dB(A) ordinance thresholdOne of the two weakest fields here. No facility in this workbook has a measured noise value.
Residential_Distance_mmModelled1.0/5Land-use class band.Anchored to Virginia JLARC 2024 (~1/3 of VA data centres within 200 ft of residential zoning)A class band, not a measured setback. Real setbacks vary by an order of magnitude within a class.
Land_Use_Context / Sensitivitycategory / 0-1Proxy2.0/5Land-use class of the facility's area and its community-sensitivity weight.Area reference table, sheet 52Assigned per area, so every facility in an estate shares a value.
Population_1km / Population_5kmpersonsModelled1.0/5Density band x pi x r^2, with a 0.60 radial decay factor applied at 5 km.Area density bands, sheet 52NOT a raster zonal statistic. Replace with GHSL or WorldPop against real coordinates before publication.
Community_Complaintscount/yrNot Available0.0/50 for every facility.No public record located0 MEANS 'no publicly documented facility-specific complaint was found'. It does NOT mean none exist.
Regulatory_Planning_Constraint0-1Reported3.0/5Cluster-level score for restrictive instruments in force (moratoria, connection bans, zoning frameworks).Regulator and grid-operator publications, cited per clusterCluster-level, so it cannot distinguish two facilities in the same market.
Documented_Objection_Record0-1Reported3.0/5Cluster-level score for the strength of the public objection / litigation record.Legislative audits, planning decisions, litigation reportingStrong for the USA and Ireland; near-absent for India, Brazil and Singapore - an evidence gap, not an absence of impact.
Local_Infrastructure_Pressure_pct%Derived2.0/5Facility capacity as a share of its cluster's total capacity.DerivedA concentration measure, not a grid-headroom measure.
Employment_Estimate_FTEjobsModelled1.0/5Capacity_MW x 5 permanent roles per MW.Industry rule of thumbHighly uncertain and varies enormously between colocation and hyperscale operating models.
P1..P6 pillar scores0-100Derived2.0/5Weighted sum of normalised sub-indicators (Methodology section 5).DerivedInherits the confidence of its weakest input; P5 and P6 are Confidence 1-2 throughout.
Composite_Score / Risk_Class0-100 / categoryDerived2.0/5Weighted mean of the six pillars; class = quartile of this dataset.DerivedRelative to this dataset only. Not an absolute risk statement about any facility.
Record_Confidence0-5Derived5.0/5Mean of the field confidences for capacity, PUE, WUE, coordinates, status, year and context.DerivedA summary; always check the per-field confidence columns before relying on a single value.
Grid emission factor (India)tCO2e/MWhReported3.0/50.710CEA CO2 Baseline Database for the Indian Power Sector (weighted average operating margin ~0.71 tCO2/MWh)National annual average; masks large sub-national and hourly variation.
Grid renewable share (India)%Reported3.0/522.0Ember / CEA generation mix ~2024 (renewables incl. large hydro as % of generation)Physical generation mix, not contracted procurement.
Benchmark PUE (India)ratioProxy2.0/51.60Uptime Institute Global Data Center Survey - Asia-Pacific regional average; same value as the source workbookRegional/industry average applied to individual sites.
Benchmark WUE (India)m3/MWhProxy2.0/52.15Source workbook India WUE (2.15 m3/MWh), derived from Indian colocation disclosuresSee the source note - several of these are climate proxies or regulatory ceilings, not measurements.
Grid emission factor (USA)tCO2e/MWhReported3.0/50.386US EPA eGRID national annual average generation emission factorNational annual average; masks large sub-national and hourly variation.
Grid renewable share (USA)%Reported3.0/523.0EIA / Ember US generation mix ~2024Physical generation mix, not contracted procurement.
Benchmark PUE (USA)ratioProxy2.0/51.50Uptime Institute Global Data Center Survey - North America regional averageRegional/industry average applied to individual sites.
Benchmark WUE (USA)m3/MWhProxy2.0/50.37LBNL 2024 US Data Center Energy Usage Report: 17.4 bn gal direct cooling water / 176 TWh (2023)See the source note - several of these are climate proxies or regulatory ceilings, not measurements.
Grid emission factor (UK)tCO2e/MWhReported3.0/50.207UK DESNZ/DEFRA Greenhouse Gas Conversion Factors, grid electricity generation factorNational annual average; masks large sub-national and hourly variation.
Grid renewable share (UK)%Reported3.0/545.0DESNZ Energy Trends / Ember GB generation mix ~2024Physical generation mix, not contracted procurement.
Benchmark PUE (UK)ratioProxy2.0/51.50Uptime Institute Global Data Center Survey - Europe regional averageRegional/industry average applied to individual sites.
Benchmark WUE (UK)m3/MWhProxy2.0/51.00Climate-based WUE proxy carried from the source workbook - WEAK EVIDENCE, no primary UK national figureSee the source note - several of these are climate proxies or regulatory ceilings, not measurements.
Grid emission factor (Ireland)tCO2e/MWhReported3.0/50.280SEAI Energy in Ireland - electricity CO2 intensityNational annual average; masks large sub-national and hourly variation.
Grid renewable share (Ireland)%Reported3.0/540.0EirGrid / SEAI renewable share of electricity generation ~2024Physical generation mix, not contracted procurement.
Benchmark PUE (Ireland)ratioProxy2.0/51.40Cool-maritime-climate benchmark; free-cooling-dominant Dublin hyperscale fleetRegional/industry average applied to individual sites.
Benchmark WUE (Ireland)m3/MWhProxy2.0/50.80Cool-climate WUE proxy (free cooling reduces evaporative demand) - MODELLED, no Irish national figureSee the source note - several of these are climate proxies or regulatory ceilings, not measurements.
Grid emission factor (Germany)tCO2e/MWhReported3.0/50.380German Environment Agency (UBA) specific CO2 emissions of the German electricity mixNational annual average; masks large sub-national and hourly variation.
Grid renewable share (Germany)%Reported3.0/555.0AGEB / Fraunhofer ISE renewable share of public net electricity generation ~2024Physical generation mix, not contracted procurement.
Benchmark PUE (Germany)ratioProxy2.0/51.45Uptime Institute Europe regional average adjusted for the Frankfurt free-cooling windowRegional/industry average applied to individual sites.
Benchmark WUE (Germany)m3/MWhProxy2.0/50.90Temperate-climate WUE proxy - MODELLED, no German national data-centre figureSee the source note - several of these are climate proxies or regulatory ceilings, not measurements.
Grid emission factor (Brazil)tCO2e/MWhReported3.0/50.110MCTI / ONS Brazilian national grid emission factor (hydro-dominant system)National annual average; masks large sub-national and hourly variation.
Grid renewable share (Brazil)%Reported3.0/587.0ONS / EPE Brazilian generation mix ~2024Physical generation mix, not contracted procurement.
Benchmark PUE (Brazil)ratioProxy2.0/51.70Source workbook Brazil PUE (1.7) - warm-humid climate colocation benchmarkRegional/industry average applied to individual sites.
Benchmark WUE (Brazil)m3/MWhProxy2.0/52.15Source workbook Brazil WUE (2.15 m3/MWh)See the source note - several of these are climate proxies or regulatory ceilings, not measurements.
Grid emission factor (Singapore)tCO2e/MWhReported3.0/50.400Singapore EMA grid emission factor (gas-dominant system)National annual average; masks large sub-national and hourly variation.
Grid renewable share (Singapore)%Reported3.0/55.0EMA Singapore Energy Statistics - solar share of generationPhysical generation mix, not contracted procurement.
Benchmark PUE (Singapore)ratioProxy2.0/51.40IMDA Green Data Centre Standard / Singapore new-build PUE requirement (<=1.3 for new; 1.4 fleet benchmark)Regional/industry average applied to individual sites.
Benchmark WUE (Singapore)m3/MWhProxy2.0/52.00Singapore regulatory WUE CEILING (<=2.0 m3/MWh) - a ceiling, not a measured mean; likely overstates actual useSee the source note - several of these are climate proxies or regulatory ceilings, not measurements.
Operator disclosure (Google)PUE / WUE / CFEReported4.0/5PUE 1.09 | WUE 0.99 | matched renewable 64.0Google Environmental Report - fleet-wide average annual PUE, average WUE and carbon-free energy percentageA FLEET-WIDE figure applied to each of that operator's individual facilities in this workbook.
Operator disclosure (Meta)PUE / WUE / CFEReported4.0/5PUE 1.09 | WUE 0.2 | matched renewable 100.0Meta Sustainability Report - fleet PUE/WUE and 100% renewable-energy matching claimA FLEET-WIDE figure applied to each of that operator's individual facilities in this workbook.
Operator disclosure (Microsoft)PUE / WUE / CFEReported4.0/5PUE 1.18 | WUE 0.3 | matched renewable 100.0Microsoft Environmental Sustainability Report - design PUE/WUE and 100% renewable purchase claimA FLEET-WIDE figure applied to each of that operator's individual facilities in this workbook.
Operator disclosure (Amazon AWS)PUE / WUE / CFEReported4.0/5PUE 1.15 | WUE 0.18 | matched renewable 100.0AWS Sustainability - global WUE 0.18 L/kWh and 100% renewable-matched claimA FLEET-WIDE figure applied to each of that operator's individual facilities in this workbook.
Operator disclosure (Equinix)PUE / WUE / CFEReported4.0/5PUE 1.42 | WUE None | matched renewable 96.0Equinix Sustainability Report - global portfolio PUE and renewable-coverage percentageA FLEET-WIDE figure applied to each of that operator's individual facilities in this workbook.
Operator disclosure (Digital Realty)PUE / WUE / CFEReported4.0/5PUE 1.45 | WUE None | matched renewable 65.0Digital Realty ESG Report - global portfolio PUE and renewable-energy coverageA FLEET-WIDE figure applied to each of that operator's individual facilities in this workbook.
Operator disclosure (STT GDC India)PUE / WUE / CFEReported4.0/5PUE 1.5 | WUE None | matched renewable NoneSTT GDC India sustainability disclosures - India portfolio design PUEA FLEET-WIDE figure applied to each of that operator's individual facilities in this workbook.
Operator disclosure (CtrlS Datacenters)PUE / WUE / CFEReported4.0/5PUE 1.42 | WUE None | matched renewable NoneCtrlS published design PUE for its Indian Tier-IV fleetA FLEET-WIDE figure applied to each of that operator's individual facilities in this workbook.
Operator disclosure (Yotta Data Services)PUE / WUE / CFEReported4.0/5PUE 1.5 | WUE None | matched renewable NoneYotta NM1 published facility PUE (datacentermap facility specification)A FLEET-WIDE figure applied to each of that operator's individual facilities in this workbook.
Operator disclosure (AirTrunk)PUE / WUE / CFEReported4.0/5PUE 1.25 | WUE None | matched renewable NoneAirTrunk published design PUE for its APAC hyperscale fleetA FLEET-WIDE figure applied to each of that operator's individual facilities in this workbook.
Market capacity anchor (IN-Mumbai Metropolitan Region)MW IT loadReported / Derived3.0/5595 MW operationalCushman & Wakefield India Data Centre Update H1 2025 - Mumbai metro operational IT load (~53% of national)The single largest source of uncertainty in every downstream figure. All facility capacities in this market scale linearly with it.
Market capacity anchor (IN-Chennai)MW IT loadReported / Derived3.0/5191 MW operationalCushman & Wakefield India Data Centre Update H1 2025 - Chennai operational IT loadThe single largest source of uncertainty in every downstream figure. All facility capacities in this market scale linearly with it.
Market capacity anchor (IN-Delhi NCR)MW IT loadReported / Derived3.0/5146 MW operationalCushman & Wakefield India Data Centre Update H1 2025 - Delhi-NCR operational IT loadThe single largest source of uncertainty in every downstream figure. All facility capacities in this market scale linearly with it.
Market capacity anchor (IN-Pune)MW IT loadReported / Derived3.0/5112 MW operationalCushman & Wakefield India Data Centre Update H1 2025 - Pune operational IT loadThe single largest source of uncertainty in every downstream figure. All facility capacities in this market scale linearly with it.
Market capacity anchor (IN-Hyderabad)MW IT loadReported / Derived3.0/5152 MW operationalResidual of the Cushman & Wakefield national total (1,280 MW, H1 2025) after the six named metros - DERIVED, not directly reportedThe single largest source of uncertainty in every downstream figure. All facility capacities in this market scale linearly with it.
Market capacity anchor (IN-Bengaluru)MW IT loadReported / Derived3.0/576 MW operationalCushman & Wakefield India Data Centre Update H1 2025 - Bengaluru operational IT loadThe single largest source of uncertainty in every downstream figure. All facility capacities in this market scale linearly with it.
Market capacity anchor (IN-Kolkata)MW IT loadReported / Derived3.0/5110 MW operationalBuilt up from facility-level disclosures (NTT Kolkata 1 = 40 MW; STT Kolkata DC2 = 34 MW) plus six further operating facilities. The Cushman & Wakefield city figure of 8 MW is irreconcilable with these two disclosures alone and is therefore NOT used - see the 62_QC_Reconciliation sheetThe single largest source of uncertainty in every downstream figure. All facility capacities in this market scale linearly with it.
Market capacity anchor (IN-Other India)MW IT loadReported / Derived3.0/525 MW operationalModelled residual for Ahmedabad/Gandhinagar, Kochi, Jaipur, Visakhapatnam, Coimbatore, Indore and Nashik - LOW CONFIDENCEThe single largest source of uncertainty in every downstream figure. All facility capacities in this market scale linearly with it.
Market capacity anchor (US-Northern Virginia)MW IT loadReported / Derived3.0/54000 MW operationalNorthern Virginia (Loudoun + Prince William + Fairfax) commissioned data-centre IT load, ~4 GW class, per Dominion Energy connected-load reporting and market trackersThe single largest source of uncertainty in every downstream figure. All facility capacities in this market scale linearly with it.
Market capacity anchor (UK-London & Slough)MW IT loadReported / Derived3.0/51300 MW operationalGreater London / Slough Trading Estate operational IT load, ~1.3 GW class, per UK FLAP-D market trackersThe single largest source of uncertainty in every downstream figure. All facility capacities in this market scale linearly with it.
Market capacity anchor (IE-Dublin)MW IT loadReported / Derived3.0/5950 MW operationalDublin metropolitan operational data-centre IT load, ~0.95 GW class; EirGrid reports data centres at ~21% of national metered electricity demandThe single largest source of uncertainty in every downstream figure. All facility capacities in this market scale linearly with it.
Market capacity anchor (DE-Frankfurt Rhein-Main)MW IT loadReported / Derived3.0/5950 MW operationalFrankfurt/Rhein-Main operational IT load, ~0.95 GW class, the largest FLAP-D marketThe single largest source of uncertainty in every downstream figure. All facility capacities in this market scale linearly with it.
Market capacity anchor (BR-Sao Paulo State)MW IT loadReported / Derived3.0/5600 MW operationalSao Paulo state operational IT load, ~0.6 GW class (Ascenty, Scala, ODATA, Equinix, Microsoft)The single largest source of uncertainty in every downstream figure. All facility capacities in this market scale linearly with it.
Market capacity anchor (SG-Singapore)MW IT loadReported / Derived3.0/51400 MW operationalSingapore national operational IT load ~1.4 GW; consistent with the source workbook's 2024 Singapore capacity valueThe single largest source of uncertainty in every downstream figure. All facility capacities in this market scale linearly with it.
Facility load factorsfractionModelled2.0/5Hyperscale 0.80 | Wholesale 0.65 | Mid colo 0.60 | Small 0.50IT-load utilisation factors. Hyperscale 0.80 reflects operator-reported high average utilisation; colocation 0.60-0.65 reflects Indian and European colocation occupancy and diversity factors reported by JLL/CBRE (India vacancy ~4-8%, but contracted-vs-drawn load is lower). LBNL uses 0.50 for whole-fleet facility power; that value is retained for the smallest/enterprise class.Single annual constants; no seasonality, no commissioning ramp.
Facility class weightsunitlessModelled2.0/5Hyperscale 30 | Wholesale 12 | Mid colo 6 | Small 1.5Judgement-based ratios reflecting typical built IT load by facility type, calibrated so that market sums reconcile to the published anchors.Judgement, not measurement. Changing these ratios redistributes capacity between operators within a market.
Facility identity, operator, addresstextReported4.0/5Facility name, operator and street/estate addressOperator websites and press releases; datacentermap.com market directories for India, USA (Northern Virginia), UK, Ireland, Germany, Brazil and SingaporeDirectory coverage is good for commercial colocation and hyperscale, weaker for enterprise-owned and government facilities. Ownership changes are not tracked after the compilation date.
Original national benchmark series 2020-2026variousReported / Modelled / Proxy2.0/5All 44 country-year rows and both audit-trail sheets, preserved verbatimThe supplied workbook 'Data_Centre_Global_Dataset_2020_2026.xlsx' and its own Sources_Methods sheetsCarried through unchanged, INCLUDING its own stated limitations. Its India carbon and renewable-share values are inconsistent with standard national factors - see 62_QC_Reconciliation.
Field dictionary

Definitions and the limitation to read first

42 fields, each with its formula, primary source and the specific way it can mislead.

FieldUnitDefinition / formulaLimitation — read this
Data_Centre_IDidISO3 country code + sequential number. Stable primary key across every sheet.Not an external identifier; do not join to third-party datasets on it.
Data_Centre_NametextFacility name as published by the operator or a market directory.Naming conventions differ between operators; some campus and building rows share a stem.
OperatortextOwning or operating company at the time of compilation.Ownership changes frequently (M&A, JV, sale-leaseback). Snapshot as at 2026-08-25.
Record_TypecategoryFacility = a single data centre building. Campus = a multi-building parent, EXCLUDED from all sums.Campus rows exist only to preserve the parent-child structure.
Country / Region / State_Province / CitytextAdministrative geography of the facility's area.City is the administrative city of the AREA, which for metro-fringe sites may differ from the marketed city.
Latitude / Longitudedecimal degreesCentroid of the facility's industrial estate, business park or suburb.AREA CENTROID, NOT a rooftop coordinate. +/-1-3 km typically, +/-5-15 km for city-centroid records.
Coordinate_PrecisioncategoryDeclares which of the two precision bands the coordinate belongs to.
StatuscategoryOperational, Under construction, Announced, Planned or Unknown.Directories do not always disaggregate status; some Operational flags are inferred from listing context.
Year_OnlineyearReported commissioning year where found; otherwise back-cast (Methodology section 6).Confidence 1 for every modelled year. Do not use for individual-site vintage claims.
Capacity_MW_IT_2026MWEnergised IT-load capacity. Reported where published; otherwise market-anchor allocation (Methodology section 3).An allocation for 1094 of 1098 facilities. Individual values are indicative; market and cluster sums are the reliable level.
Capacity_MW_UltimateMWCapacity at full build-out of the identified pipeline, before the status energisation factor.Assumes announced and planned schemes complete at the same class weight as built stock.
PUEratioOperator fleet/design PUE where published; otherwise the country-climate benchmark.A fleet average applied to one site. Real site PUE varies with load factor, age and season.
Load_FactorfractionAverage IT-load utilisation by facility class (Hyperscale 0.80, Wholesale 0.65, Mid colo 0.60, Small 0.50).Single annual constant; ignores ramp-up on newly commissioned halls.
Energy_Consumption_MWh_yrMWh/yrCapacity x 8,760 x Load_Factor x PUE.No site is metered here. Error compounds capacity error, load-factor error and PUE error.
Energy_Intensity_MWh_per_MW_yrMWh/MW/yr8,760 x Load_Factor x PUE.Varies only by class and country in this build; it is not a site-specific efficiency measure.
Grid_Electricity_Dependence_pct%Set to 100 for every facility.No public evidence of material on-site generation was located at any facility. Treat as an upper bound.
Renewable_Grid_pct%National grid-average renewable share of GENERATION.A physical grid mix, NOT contracted or matched procurement. Do not confuse with the next field.
Renewable_Matched_pct%Operator-published renewable matching / carbon-free-energy percentage, where one exists.Annual matching, not hourly delivery, except where the operator states otherwise (Google reports hourly CFE).
Water_Consumption_m3_yrm3/yrEnergy_MWh x WUE.On-site cooling water only. Excludes upstream water embodied in electricity generation, which is often larger.
WUEm3/MWh (= L/kWh)Operator fleet WUE where published; otherwise country-climate benchmark.UK, EU and Irish values are climate proxies with no primary national data-centre figure. Singapore's is a regulatory CEILING.
Water_Stress_Score / Label0-5 / categoryWRI Aqueduct-informed baseline water-stress band for the facility's basin.NOT a real Aqueduct basin lookup against the facility coordinate. Assigned per reference AREA.
Water_Stress_Weighted_Demand_m3m3/yrWater_m3 x (water-stress score / 5). A scarcity-adjusted demand.Linear scarcity weighting is a convention, not a hydrological model.
Cooling_Water_DependencecategoryBanded from WUE: >1.5 evaporative-dominant, 0.5-1.5 hybrid, <0.5 air-cooled/closed-loop.Inferred from a water ratio, not from the installed plant.
Carbon_Emissions_Location_tCO2e_yrtCO2e/yrEnergy_MWh x national grid emission factor.LOCATION-BASED Scope 2. National averages hide large sub-national variation (~6x across US eGRID subregions).
Carbon_Emissions_Market_tCO2e_yrtCO2e/yrEnergy_MWh x grid factor x (1 - operator matched-renewable %).Only populated where the operator publishes a matching percentage. Annual matching is not hourly decarbonisation.
Emission_Intensity_tCO2e_per_MWhtCO2e/MWhThe national grid emission factor applied to that facility.Uniform within a country by construction.
Waste_Heat_MW_thermal / _TJ_yrMWth / TJ/yrEnergy_MWh / 8,760, and the same energy expressed as TJ per year.An average annual heat-rejection RATE, not a measured local temperature effect.
Cooling_TechnologycategoryInferred from WUE band.A guess at plant type from a water ratio. Replace with planning-application data where available.
Mean_Annual_Temperature_Cdeg CLong-run mean annual air temperature for the facility's area.Annual mean; ignores the summer peak that actually drives cooling and heat-island effects.
Heat_Island_ProxyMWth x k-persons/km2Waste_Heat_MW x resident density / 1,000.A composite index with no physical units meaning. Comparative only.
Noise_dBdB(A) @ ~50 m50 + 10 x log10(Capacity_MW), clipped to [45,85].One of the two weakest fields here. No facility in this workbook has a measured noise value.
Residential_Distance_mmLand-use class band.A class band, not a measured setback. Real setbacks vary by an order of magnitude within a class.
Land_Use_Context / Sensitivitycategory / 0-1Land-use class of the facility's area and its community-sensitivity weight.Assigned per area, so every facility in an estate shares a value.
Population_1km / Population_5kmpersonsDensity band x pi x r^2, with a 0.60 radial decay factor applied at 5 km.NOT a raster zonal statistic. Replace with GHSL or WorldPop against real coordinates before publication.
Community_Complaintscount/yr0 for every facility.0 MEANS 'no publicly documented facility-specific complaint was found'. It does NOT mean none exist.
Regulatory_Planning_Constraint0-1Cluster-level score for restrictive instruments in force (moratoria, connection bans, zoning frameworks).Cluster-level, so it cannot distinguish two facilities in the same market.
Documented_Objection_Record0-1Cluster-level score for the strength of the public objection / litigation record.Strong for the USA and Ireland; near-absent for India, Brazil and Singapore - an evidence gap, not an absence of impact.
Local_Infrastructure_Pressure_pct%Facility capacity as a share of its cluster's total capacity.A concentration measure, not a grid-headroom measure.
Employment_Estimate_FTEjobsCapacity_MW x 5 permanent roles per MW.Highly uncertain and varies enormously between colocation and hyperscale operating models.
P1..P6 pillar scores0-100Weighted sum of normalised sub-indicators (Methodology section 5).Inherits the confidence of its weakest input; P5 and P6 are Confidence 1-2 throughout.
Composite_Score / Risk_Class0-100 / categoryWeighted mean of the six pillars; class = quartile of this dataset.Relative to this dataset only. Not an absolute risk statement about any facility.
Record_Confidence0-5Mean of the field confidences for capacity, PUE, WUE, coordinates, status, year and context.A summary; always check the per-field confidence columns before relying on a single value.

Where the workbook's bottom-up total diverges from a published market figure, the divergence is recorded in the quality-control table rather than reconciled away. Reading those rows is the fastest way to understand how much weight the totals can bear.